Identify The Failed Hard Drive - Dell EMC SC4020 Owner's Manual

Table of Contents

Advertisement

Identify the Failed Hard Drive

To determine which hard drive failed, use the Dell Storage Manager Client.
Steps
1. Use the Dell Storage Manager Client to connect to the Storage Center.
2. Click the Hardware tab.
3. In the Hardware tab navigation pane, select the Storage Center.
4. In the Hardware Alerts area, find the hardware alert that identifies the expansion enclosure with the failed hard drive.
Figure 14. Hardware Alert Identifying the Expansion Enclosure with the Failed Hard Drive
5. In the Hardware tab navigation pane, expand the expansion enclosure identified in the previous step.
6. Select Disks. The status of each hard drive is displayed in the Disks tab.
7. Select the failed hard drive. The location of the failed hard drive is displayed in the Disk View tab.
Figure 15. Front View of the Expansion Enclosure Showing the Failed Hard Drive
Replacing SC4020 Storage System Components
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents