Activating, Deactivating Protection Zones (Cprot, Nprot) - Siemens SINUMERIK 840D sl Programming Manual

Job planning
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Protection zones

4.2 Activating, deactivating protection zones (CPROT, NPROT)

During definition of the protection zones
• no cutter or tool nose radius compensation,
• no transformation,
• no frame must be active.
Nor must reference point approach (G74), fixed point approach (G75), block search stop or
program end be programmed.
4.2
Activating, deactivating protection zones (CPROT, NPROT)
4.2
Function
Activating and preactivating previously defined protection zones for collision monitoring and
deactivating protection zones.
The maximum number of protection zones, which can be active simultaneously on the same
channel, is defined in machine data.
If no toolrelated protection zone is active, the tool path is checked against the workpiece-
related protection zones.
Note
If no workpiece-related protection zone is active, protection zone monitoring does not take
place.
Programming
CPROT (n,state,xMov,yMov,zMov)
NPROT (n,state,xMov,yMov,zMov)
Parameters
CPROT
NPROT
n
state
xMov,yMov,zMov
4-4
Call channel-specific protection zone (for NCU 572/573 only)
Call machine-specific protection zone
Number of protection zone
Status parameter
0 = Deactivate protection zone
1 = Preactivate protection zone
2 = Activate protection zone
3 = Preactivate protection zone with conditional stop
Move defined protection zone on the geometry axes
Programming Manual, 03/2006 Edition, 6FC5398-2BP10-1BA0
Job planning

Advertisement

Table of Contents
loading