8.5
Adjust the air pressure (pneumatic systems)
8.5.1 Pull up pressure adjustment valve. Set adjustment valve to the
desired value on manometer by turning it clockwise or counter
clockwise. Then lock the valve by pressing it down.
8.5.2 Set the air pressure between 6 and 8 BAR. If air pressure
drops below the stated values, accessories operating with
pneumatic power do not work.
8.5.3 Conditioner unit accumulates the water in the air in the
collection container so that it won't damage pneumatic
components. At the end of the working day, empty the
accumulated water by opening water discharge valve under the
collection container.
8.5.4 In order to put oil to the oil tank, remove the reservoir by
turning. Oils recommended by the manufacturer are; TELLUS
C10 / BP ENERGOL HLP 10 / MOBIL DTE LIGHT / PETROL
OFİSİ SPINDURA 10.