Omron SYSMAC CS Series Programming Manual page 286

Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

PC Comparison Charts
PC Comparison Charts
Item
Table Data
SET STACK
Processing
Instructions
PUSH ONTO
STACK:
FIRST IN
FIRST OUT
LAST IN
FIRST OUT
FIND MAXI-
MUM/FIND
MINIMUM
DATA
SEARCH
FRAME
CHECKSUM
SUM
SWAP BYTES SWAP
DIMENSION
RECORD
TABLE:
SET
RECORD
LOCATION
GET
RECORD
LOCATION
Data Con-
SCALING
trol Instruc-
SCALING 2
tions
SCALING 3
PID CON-
TROL
LIMIT CON-
TROL
DEAD BAND
CONTROL
DEAD ZONE
CONTROL
AVERAGE
Mne-
CJ Series
monic
SSET
Yes (Four words
Yes (Four words
of stack control
of stack control
information.
information.
Number of words
Number of words
specified in
specified in
binary: 5 to
binary: 5 to
65535)
65535)
PUSH
Yes
Yes
FIFO
Yes
Yes
LIFO
Yes
Yes
MAX,
Yes (Two words
Yes (Two words
MIN
in control data
in control data
field. Table length
field. Table length
specified in
specified in
binary: 1 to
binary: 1 to
FFFF)
FFFF)
SRCH
Yes (Table length
Yes (Table length
specified in
specified in
binary: 1 to
binary: 1 to
FFFF. PC mem-
FFFF. PC mem-
ory address out-
ory address out-
put to IR0.
put to IR0.
Number of
Number of
matches can be
matches can be
output to DR0)
output to DR0)
FCS
Yes
Yes
SUM
Yes (Same as
Yes (Same as
C200HX/HG/HE:
C200HX/HG/HE:
Sum possible for
Sum possible for
bytes as well as
bytes as well as
words.)
words.)
Yes (Can be
Yes (Can be
used for data
used for data
communications
communications
and other appli-
and other appli-
cations.)
cations.)
DIM
Yes
Yes
SETR
Yes
Yes
GETR
Yes
Yes
SCL
Yes
Yes
SCL2
Yes
Yes
SCL3
Yes
Yes
PID
Yes (Output can
Yes (Output can
be switched
be switched
between 0% and
between 0% and
50% when PV =
50% when PV =
SV. PID and
SV. PID and
sampling period
sampling period
specified in
specified in
binary.)
binary.)
LMT
Yes
Yes
BAND
Yes
Yes
ZONE
Yes
Yes
AVG
Yes (Number of
Yes (Number of
scans specified in
scans specified in
binary)
binary)
CS Series
C200HX/HG/HE
No
No
No
No
Yes (One word in
control data field.
Table length
specified in BCD:
1 to 999)
Yes (Table length
specified in BCD:
1 to 6556. PC
memory address
output to C+1.
Number of
matches cannot
be output to DR0)
Yes
Yes (Sum possi-
ble for bytes as
well as words.)
No
No
No
No
Yes
No
No
Yes (PID and
sampling period
specified in BCD)
No
No
No
Yes (Number of
scans specified in
BCD)
Appendix A
Appendix A
CVM1/CV Series
CQM1H
Yes (Four words
No
of stack control
information.
Number of words
specified in BCD:
3 to 9999)
Yes
No
Yes
No
Yes
No
Yes (One word in
Yes (One word in
control data field.
control data field.
Table length
Table length
specified in BCD:
specified in BCD:
1 to 999)
1 to 999)
Yes (Table length
Yes (Table length
specified in BCD:
specified in BCD:
1 to 9999. PC
1 to 6556. PC
memory address
memory address
output to IR0.
output to C+1.
Number of
Number of
matches cannot
matches cannot
be output to DR0)
be output to DR0)
No
Yes
Yes (Sum possi-
Yes (Sum possi-
ble for words
ble for bytes as
only.)
well as words.)
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
Yes (PID and
Yes (PID and
sampling period
sampling period
specified in BCD)
specified in BCD)
(*1)
Yes (*1)
No
Yes (*1)
No
Yes (*1)
No
No
Yes (Number of
scans specified in
BCD)
267