02R96
change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001011 0B
ADDRESS
00100001 21
0aaaaaaa aa
0aaaaaaa aa
0aaaaaaa aa
DATA
0ddddddd dd
0ddddddd dd
:
EOX
11110111 F7
Meter data uses the unmodified DECAY value of the DSP. For the inter-
pretation of the value, refer to the PARAMETER CHANGE PARAMETER
NUMBER LIST.
12.3.22 Parameter request (Remote Meter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the parameter specified by Address (refer to PA-
RAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted
on the [Rx CH] at 50 msec intervals for a duration of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00001011 0B
ADDRESS
00100001 21
0aaaaaaa aa
0aaaaaaa aa
0aaaaaaa aa
DATA
0cccccccccc
0ccccccccCc
EOX
11110111 F7
12.3.23 Parameter change (Remote Time Counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001011 0B
ADDRESS
00100001 22
0000tttt 0t
DATA
0ddddddd dd
0ddddddd dd
0ddddddd dd
0ddddddd dd
192
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
02R96
Address UU
Address UL
Address LU
Address LL
Data1 H
Data1 L
End of exclusive
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
02R96
Address UU
Address UL
Address LU
Address LL
Count H
Count L
End of exclusive
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
02R96
Remote Time Counter
0:Time Code, 1: Measure, Beat, Clock
Hour / Measure H
Min / Measure L
Sec / Beat
Frame / Clock
End of exclusive
EOX
11110111 F7
12.3.24 Parameter request (Remote Time Counter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the
[Rx CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission
will be halted immediately.
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Remote Time Counter
ADDRESS
00100001 22
0:Transmission request,
0aaaaaaa aa
0x7F:Transmission stop request
End of exclusive
EOX
11110111 F7
12.3.25 Parameter change (Automix Status)
When transmission is enabled by receiving a Request of Automix status,
the Automix Status data is transmitted every second for 10 seconds. When
you want to transmit the Automix Status information continuously, the
Request must be transmitted continuously minimum within 10 seconds
interval. The data is transmitted continuously while the transmission is en-
abled, even when the Automix Status on the 02R96 has been changed.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When the transmission is set to enable by receiving a Request. The Auto-
mix Status data is transmitted on the [Rx CH] channel every second for 10
seconds. The data is transmitted continuously while the transmission is
enabled, even when the Automix Status on the 02R96 has been changed.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Automix Status
ADDRESS
00100011 23
00000000 00
Automix Status H
DATA
0000dddd 0d
Automix Status L
0000dddd 0d
End of exclusive
EOX
11110111 F7
12.3.26 Parameter request (Automix Status)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When the data is received, the Automix Status data is transmitted on the
[Rx CH] every second for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission
will be halted immediately (disable).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Automix Status
ADDRESS
00100011 23
0:Transmission request,
0aaaaaaa aa
0x7F:Transmission stop request
End of exclusive
EOX
11110111 F7