1-32 ENCODER (etc.) Test
Contents: From CH1, check the rotation response of
Encoder of other than CH24.
The way of operation is the same as 1-31.
Example of execution screen
--- ENCODER(etc.) ---
OK
EFFECT1
OK EFFECT2
OK EFFECT3
OK EFFECT4
OK PAN/SURROUND
OK THRESHOLD
OK PANGE
OK ATTACK
OK DECAY
OK HOLD
OK LOW-F
OK LOW-G
Expression
CCW >----------------CW
of other than
Joystick
1-36 METER LED Test
Contents: Visually check if MB02R96's LEDs and
7-seg LEDs light correctly in the order
specified.
Example of execution screen
--- METER LED ---
OK
1 Channel Bargraph
NG 2 Stereo Bargraph
NG 3 Others
[ENTER] key to Start
OK
NG
EXIT ([DEC Key]->[ENTER Key])
The orders of lighting are as follows:
1) Channel bar graph is turned on. (LED lighting order: CH1:
Lower→Upper..CH24: Lower→Upper)
2) Stereo bar graph is turned on. (LED lighting order: Stereo
L: Lower→Upper, Stereo R: Lower→Upper)
3) Other lighting
(CH1-24_L → CH25-48_L → CH49-56_L → INPUT PRE
EQ → PRE FADER → POST FADER → PEAK HOLD
SW → CH1-24_R → CH25-48_R → CH49-56_R →
1-24 SW → 25-48 SW → MASTER SW → REMOTE SW
→ CONTROL ROOM → OUTPUT PRE EQ → PRE
FADER → POST FADER)
If judged as OK, the
check moves to the
OK LOW-MID-F
next channel.
OK LOW-MID-G
If not OK, press the
NG HIGH-MID-F
[DEC] key to move to
NG HIGH-MID-G
the next check.
NG HIGH-F
NG HIGH-G
NG MONITOR LEVEL
NG WHEEL
NG Joystick(L-R)
NG Joystick(D-U)
Expression of Joystick
L >----------------R
(When L-R finished,
D >----------------U
moves to D-U.)
1-37 METER SW Test
Contents: Press the SWs of MB02R96 to check if the
corresponding LED turns ON/OFF.
Example of execution screen
--- METER SW ---
OK
METER SW
OK
NG
EXIT ([DEC Key]->[ENTER Key])
Correspondence between SWs and LEDs is as follow:
Switch
INPUT METERING POSITION
OUTPUT METERING POSITION
PEAK HOLD
1-24
25-48
MASTER
REMOTE
CONTROL ROOM
1-98 MESSAGE LOG
Contents: Displays the inspection result log.
Example of execution screen
--- MESSAGE LOG ---
[ 2 BATT]
NG:BATT (2.56V)
[ 7 MIDI]
OK: SCI2
BACK: [UP] NEXT: [DOWN] EXIT: [ENTER] Page 2
• The [↓] key displays the next page.
• The [↑] key displays the previous page.
• The [ENTER] key ends the screen.
• The SOLO [CLEAR] key clears the log.
• The "NG" lines will be highlighted.
Limitations:
A maximum of 999 pages can be displayed.
Logs after that cannot be loaded. Clear the log in
this event.
The log will also be cleared when the service
inspections are ended.
02R96
LED
POST FADER LED
POST FADER LED
PEAK HOLD
1-24
25-48
MASTER
REMOTE
CONTROL ROOM
159