Using Bulk Dump - Yamaha O2R96 Service Manual

Digital mixing console/ peak meter bridge/wooden side panels
Hide thumbs Also See for O2R96:
Table of Contents

Advertisement

02R96

USING BULK DUMP

02R96 data can be stored to an external MIDI device, such as
a MIDI data filer, by using MIDI Bulk Dump.
1 Use the DISPLAY ACCESS [MIDI] button to locate
the Bulk Dump page.
2 To transmit data, use the CATEGORY parameters
to select the type of data you want to transmit, select
the TRANSMIT button, and then press [ENTER].
3 To receive data, use the CATEGORY parameters to
select the type of data you want to receive, select
the REQUEST button, and then press [ENTER].
The INTERVAL parameter sets the interval between data
packets during transmission.
The CATEGORY parameters can be set as follows:
ALL: All data.
SCENE MEM: ALL Scenes, individual Scenes, or current
(i.e., the Edit buffer).
AUTOMIX: ALL Automixes, individual Automixes, or the
current Automix.
LIBRARY: The following libraries: EQ, Gate, Comp,
Channel, Effects, Bus to Stereo, Input Patch, Output Patch,
Surround Monitor. For each library you can specify ALL user
memories, individual user memories, and for the Bus to
Stereo, Input Patch, Output Patch, Surround Monitor libraries
you can also specify the current settings.
BANK: User Defined Remote Layer banks, User Defined
Plug-Ins banks, or the User Defined Keys banks. For each
item you can specify ALL or individual banks.
SETUP MEM: 02R96 setup data (i.e., system settings).
PGM TABLE: Scene to MIDI Program Change table.
CTL TABLE: Parameter to MIDI Control Change table.
PLUG-IN: The settings of any installed Y56K cards. You
can specify ALL Slots or Slot 3 or 4.
176

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb02r96Sp02r96

Table of Contents