02R96
34.
DSUB Cable
(Time required: About 15 minutes)
34-1. Remove the rear panel. (See procedure 31.)
34-2. Remove the screw marked [130]. The cable holder
can then be removed. (Fig.14)
34-3. Remove the DSUB cable with the bushing. (Fig.14)
The bushing is not part of the DSUB cable.
When you replace the DSUB cable, you should
remove the bushing from the cable, and attach
in the new cable.
Meter angle L
<Left side view>
<Front view>
[140B]
<Bottom view>
<Rrar view>
50
[D]
[D]: Bind Head Screw
[140B]: Bind Head Tapping Screw-B
A4.0X8 MFZN2BL (VP156800)
Photo.7
Front panel
[140B]
[140B]
A3.0X8 MFZN2BL (VP157000)
Fig.13
MB02R96
<Right side view>
Rear panel
[140B]