7 Reprocessing methods according to ISO 17664

7.2.4 Automated internal cleaning

For alternative interior cleaning, KaVo recommends thermodisinfectors in
accordance with EN ISO 15883-1, which are operated with alkaline clean‐
ing agents with a pH value of max. 10 (e. g. Miele G 7781 / G 7881 – Vali‐
dation was carried out with program "VARIO-TD", cleaning agent
"neodisher® mediclean", neutralisation agent "neodisher® Z" and rinsing
agent "neodisher® mielclear" and only applies to the
compatibility of materials with KaVo products).
▶ For program settings as well as cleansers and disinfectants to be
used, please refer to the Instructions for Use of the thermodisinfector
(complying with max. pH value of 10).
▶ In order to prevent negative effects on the medical device, make sure
that the interior and the exterior of the medical device are dry after
completion of the cycle, and then grease it immediately with servicing
agents from the KaVo care system.