3. Installation
3.4.2 MPA valve terminal with MP connection (only MPA1)
Sum
Maximum number of valve loca
of valve
tions which can occupy two ad
locations
dresses
4
all valve locations
8
all valve locations
12
all valve locations
16
8 valve locations
20
4 valve locations
24
−−−
1) Two solenoid coils per valve location can be controlled.
2) One solenoid coil per valve location can be controlled.
Table 3/6: Address assignment of the MPA valve terminal with MP connection (only
MPA1) type MPA1−MP−...
Festo P.BE−MPA−EN en 0502b
The addresses must be assigned in ascending order with
out gaps
Counting begins on the valve terminal from left to right
(see diagram).
Depending on the electronic module, a valve location oc
cupies one or two addresses (see table).
The following assignment applies:
Solenoid coil 14 occupies the lower−value address,
solenoid coil 12 occupies the higher−value address.
1)
Valve locations which occupy one
2)
address each
−−−
−−−
−−−
8 valve locations
16 valve locations
all valve locations
3−27