4. Commissioning
Locking actuation of the manual override (reset manually)
Table 4/5: Locking actuation of the manual override
4−12
Please note
The locking actuation of the manual override is only poss
ible if a manual override cap is not fitted.
Operation
Use a screwdriver (max. blade
·
width 2.5 mm) to press down the
plunger of the manual override
until the valve switches.
Then turn the plunger in a clock
·
wise direction as far as possible.
Leave the plunger in position.
·
Then turn the plunger in an anti−
·
clockwise direction as far as poss
ible.
Then release the plunger.
·
Reaction of the valve
The valve:
moves to the switch position
remains in the switch position
moves back to the basic position
(not with double−solenoid valve,
Ident. code J)
Festo P.BE−MPA−EN en 0502b