MS300 (IP66 / NEMA 4X) Communication Parameters when Connected to EtherNet
When you connect the MS300 (IP66 / NEMA 4X) to EtherNet, set up the communication parameters based
on the table below. The EtherNet master can read and write frequency command words and operation command
words for the MS300 (IP66 / NEMA 4X) after you set the communication parameters.
Parameter
Frequency command
00-20
source
Operation command
00-21
source
Decoding method for
09-30
communication
09-75
IP setting
09-76
IP address 1
09-77
IP address 2
09-78
IP address 3
09-79
IP address 4
09-80
Netmask 1
09-81
Netmask 2
09-82
Netmask 3
09-83
Netmask 4
09-84
Default gateway 1
09-85
Default gateway 2
09-86
Default gateway 3
09-87
Default gateway 4
Basic Registers
R/W
BR#
#0
R
Model name
#1
R
Firmware version
Release date of the
#2
R
version
#11
R/W
Modbus Time-out
#13
R/W
Keep Alive Time
LED Indicator & Troubleshooting
LED Indicators
LED
Status
Green
POWER
Green
:
Operation
-10–50 °C (temperature), 90 % (humidity)
:
Storage
-25–70 °C (temperature), 95 % (humidity)
International standards
IEC 61800-5-1, IEC 60068-2-6 / IEC 61800-5-1, IEC 60068-2-27
Function
Current Set Value
Content
Defined by the system. The model code of CMM-MOD01=H'0103.
Displays the current firmware version in hex, e.g. H`0100 indicates
firmware version V1.00.
Displays the date in decimal form. 10,000s digit and 1,000s digit are
for "month"; 100s digit and 10s digit are for "day".
For 1 digit: 0 = AM; 1 = PM.
Pre-defined setting: 500 (ms)
Pre-defined setting: 30 (s)
Indication
On
Power supply in normal status
Off
No power supply
:
Definition of Parameter Values
The frequency command is controlled by
8
communication card.
The operation command is controlled by
5
communication card.
Decoding method for the Delta AC motor
0
drive.
0
Static IP(0) / Dynamic distribution IP(1)
192
IP address 192.168.1.5
168
IP address 192.168.1.5
1
IP address 192.168.1.5
5
IP address 192.168.1.5
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
255
Netmask 255.255.255.0
0
Netmask 255.255.255.0
192
Default gateway 192.168.1.1
168
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
1
Default gateway 192.168.1.1
Set Value
No action is required
Check the power supply
8-8
Corrective Action

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents