Troubleshooting
Circumstance
No signs of power
to the incubator.
When temperature
is too high /
When temperature
is too low
When humidity
is too high /
When humidity
is too low
The machine makes
some noise.
- A little noisy occurs from
the inside of circulation fan.
Dew forms in
the incubator.
- Dew condensation is normal
with high humidity incubation.
When pumping
is slow
Test the incubator to be sure that the incubator works without any problem before placing eggs in the incubator.
Please ensure you remember how to use the machine and maybe re-read instructions.
DIGITAL INCUBATOR
6. Product Information
Items to be confirmed
▶ Check electric cord is properly connected.
▶ Check if there is a power outage.
▶ Check whether the plug is damaged.
▶ Check the fuse is not blown.
[Refer to the page 22]
▶ Check your setting temperature.
▶ Check the air circulation FAN is working.
▶ Initialize the incubator.
[Refer to the page 16]
▶ Check water is enough.
▶ Check setting humidity.
▶ Initialize the incubator.
[Refer to the page 16]
<When Low>
▶ Check if evaporating pad is fit well.
▶ Check if view window is closed completely.
<When High>
▶ Check ambient conditions.
▶ Check if there is water in bottom body.
▶ Check whether you put anything
on the incubator.
▶ Check if there is any vibration, or check
the incubator set on a table.
▶ Check if there is any hatching debris
such as feather or eggs-shell in the
incubator FAN.
▶ Check if incubation room temperature is
too low.
▶ Check Silicon Tube
Insect Incubator Rcom Max 70 User Manual
(2) Troubleshooting
Solutions
▶ Connect the cord again.
▶ Check the main socket with any other
electric appliances.
▶ Try to insert to another outlet.
▶ Replace the spare fuse in the fuse box.
(250V 2.0A)
▶ Set the temperature as required.
▶ Take the power plug out of the outlet,
and disassemble the main body for
cleaning around the air circulation fan
with brush.
▶ Supply water.
▶ Set required humidity.
<When Low>
▶ If evaporating pad does not fit well,
humidification device will not work well.
▶ Close view window exactly.
<When High>
▶ Adjust the conditions of room
temperature [Refer to the page 8]
▶ Remover water inside of bottom body.
▶ Ensure the incubator is not touching
any other items and nothing is on
top of the unit.
▶ Move the incubator to a flat and even
surface.
▶ Unplug the power supply and
disassemble the main body for cleaning
the egg turning tray and gear.
▶ Check conditions of incubation room,
and adjust as required.
▶ Adjust APS speed hole with screw
driver.
23