5.1.4 Media Sensor Calibration (for the Black Mark Sensor)

1. Turn off the printer.
2. Press and hold the Feed/Pause button, and then turn on the printer.
3. Release the button after the green/red LED flashes five times and the LED is lit in green.
Note
The LED color will change as follows:
Amber (lit)  red/amber (5 times)  amber (5 times)  green/red (5 times)  green (5 times) 
red (5 times)  green (lit)

5.1.5 Media Sensor Calibration (for the Gap Sensor)

1. Turn off the printer.
2. Press and hold the Feed/Pause button, and then turn on the printer.
3. Release the button after the green LED flashes five times and the LED is lit in red.
Note
The LED color will change as follows:
Amber (lit)  red/amber (5 times)  amber (5 times)  green/red (5 times)  green (5 times) 
red (5 times)  green (lit)

5.1.6 Skip the AUTO.BAS program

You can upload the AUTO.BAS program to the printer's flash memory so that it runs
automatically at startup, but if you do not want it to run automatically, follow these steps:
1. Turn off the printer.
2. Press the Feed/Pause button, and then turn on the printer.
3. Release the button when the LED is lit in green.
Note
The LED color will change in the following order:
Amber (lit)  red/amber (5 times)  amber (5 times)  green/red (5 times)  green (5 times) 
red (5 times)  green (lit)
4. The printer will start without running the AUTO.BAS program.