The Read/Write SNMP Community parameter specifies a community sup-
ported by the RangeLAN802 Access Point. Actions permitted by this commu-
nity are "read-write" (GET, GET-NEXT, and SET).
The Read/Write SNMP Manager IP Address specifies the IP address of the
SNMP manager which is permitted to use the Read/Write SNMP Community.
An address of 0.0.0.0 indicates any manager may use the community.
The SNMP Trap Community parameter specifies the community that will be
used by the RangeLAN802 Access Point when generating TRAP PDUs
(Protocol Data Units) to remote managers.
The Trap Target Address specifies the IP address of the device to which
generated TRAP PDUs (Protocol Data Units) will be sent. A value of 0.0.0.0
disables trap generation.
Authentication Traps are sent to the Trap Target Address whenever anyone
attempts to SNMP manage the RangeLAN802 Access Point with an invalid
community or from an invalid community. You may enable or disable the
sending of these traps.
A Disassociation Trap is sent by the RangeLAN802 Access Point when a
station is disassociating from it. The trap includes the MAC address of the
Access Point which is losing a station. This trap may be enabled or disabled.

SNMP Supported Traps

The following traps are supported by the RangeLAN802 Access Point and are
sent to the SNMP manager defined by the Trap Target Address when they
occur.
MIB II Traps
Cold Start - Sent when the RangeLAN802 Access Point powers on or reboots.
Link Up - Sent by each interface at start-up or after coming back up following
a port administrative status command.