Operation; General; Start--Up - ESAB A2 S GMAW Mini Master Instruction Manual

Table of Contents

Advertisement

GB
5

OPERATION

5.1

General

General safety regulations for the handling of the equipment appear from
page 64. Read through before you start using the equipment!
Select wire type and shielding gas so that the weld material is as close as
S
possible to the analysis of the base material. Select wire size and welding data in
accordance with the values recommended by the consumables supplier.
Thorough joint preparation is necessary to achieve a good weld result.
S
NOTE! The width of the joint gap must be uniform.
To minimise the risk of heat crack formation the width of the weld must be
S
greater than the penetration depth.
Always carry out a test weld with the same joint type and plate thickness as the
S
workpiece to be produced.
For control and adjustment of the welding head and welding power source, see
S
the instruction manual for the A2--A6 Process Controller.
For the replacement of wear parts, see table on page 77.
S
5.2
Start- -up
NOTE!
The wire drum is not included in the delivery of the welding head in MIG design.
Fitting the wire drum
Fit the wire drum (1) on the brake hub (2).
S
Check that the carrier (3) is in the correct position.
NOTE! The maximum angle for the wire bobbin is 25°.
At extreme angles, wear will occur on the brake hub
locking mechanism and the wire bobbin will slide off
the brake hub.
IMPORTANT!
To prevent the reel sliding off the hub: Lock the reel in place
by turning the red knob as shown on the warning label atta-
ched next to the hub.
fha8o1ea
- - 70 - -