ESAB A2 S GMAW Mini Master Instruction Manual page 11

Table of Contents

Advertisement

GB
Check that the feed rollers (1, 4) and the contact nozzle (7) are of the correct
S
dimension for the wire size selected.
NOTE!
The feed rollers are marked with their respective groove diameter (D) on the
opposite side of the roller.
Undo the pressure devices (10) and put up the pressure arms (11).
S
Put the end of the wire through the wire guide nipple (12).
S
Locate the end of the wire in the groove of the feed roller (1) and feed it through
S
the intermediate nozzle (3).
Locate the end of the wire in the groove of the other feed roller (4) and feed it
S
through the outlet nozzle (9).
Put down the pressure arms (11) and adjust the wire tension on the feed rollers
S
(1, 4) by way of the pressure devices (10).
Do not tighten down too hard.
Feed the wire forward 30 mm by pressing
S
Process Controller.
fha8o1ea
on the control box A2--A6
- - 71 - -