Setting this parameter allows a stable weight display to be obtained.
To increase the effect (weight more stable) increase the value (from 0 to 9, default 4).
As seen in the diagram:
- By confirming the message, the currently programmed filter value is displayed.
- By changing and confirming the value, the weight is displayed and it will be possible to
experimentally verify its stability.
- If stability is not satisfactory, confirming brings back the message and the filter may be
modified again until an optimum result is achieved.
The filter enables to stabilise a weight as long as its variations are smaller than the corresponding
"response time". It is necessary to set this filter according to the type of application and to the full
scale value set.
FILTER VALUE
0
1
2
3
4 (default)
5
6
7
8
9
+
RESETTABLE WEIGHT SETTING FOR SMALL WEIGHT CHANGES
(from 0 to max full scale; default: 300; considered decimals: 300 – 30.0 – 3.00 – 0.300): this
parameter indicates the maximum weight value resettable by external contact, keypad or serial
protocol.
FILTER ON THE WEIGHT
Response times
[ms]
80
190
260
450
900
1700
2500
4200
6000
7500
ZERO PARAMETERS
Display and serial port refresh
- 13 -
frequency
[Hz]
80
80
40
26
13
13
13
10
10
5