weight in the registers "weight value corresponding to ZERO of the analog output H" (40043) and
"weight value corresponding to ZERO of the analog output L" (40044). After writing the value, send
the command 99 from the "Command Register" to save it in EEPROM memory.
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
INPUTS REGISTER (40033)
(reading only)
Bit 0
INPUT 1 Status
Bit 1
INPUT 2 Status
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
STATUS REGISTER (40007)
Cell Error
AD Convertor malfunction
Maximum weight exceeded by 9 divisions
Gross weight higher than 110% of full scale
Gross weight beyond 999999 or less than -999999
Net weight beyond 999999 or less than -999999
Gross weight negative sign
Net weight negative sign
Net display mode
Weight stability
Weight within ±¼ of a division around ZERO
INPUTS AND OUTPUTS REGISTERS
OUTPUTS REGISTER (40034)
(reading only)
Bit 0
OUTPUT 1 Status
Bit 1
OUTPUT 2 Status
Bit 2
OUTPUT 3 Status
Bit 3
OUTPUT 4 Status
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
- 32 -