SENSOR CM2K
E109
5. CIRCUIT
CORRECTOR CM2K
E110
5. CIRCUIT
SENSOR CM2K
E111
6. CIRCUIT
CORRECTOR CM2K
E112
6. CIRCUIT
SENSOR CM2K
E113
7. CIRCUIT
Technical manual - THE DIGITAL BOILER CONTROLLER Cm-Pelet set_Touch 14-90 kW
Possible cause: Interruption in the cables between the 5
circuit sensor and CM2K, connections on the CM2K, cold
junction or defective sensor
Boiler status: The boiler operates normally, the 5 CM2K
circuit stops to operate, stops (turns off) the pump.
Troubleshooting: Call an authorized serviceman who will
check the sensor position, check the damage/accuracy of the
sensor and cable, check the contacts on the connectors, check
the sensor's ohm resistance.
Possible cause: Interruption in the cables between the 5
circuit corrector and CM2K, connections on the CM2K, cold
junction or defective corrector
Boiler status: The boiler operates normally, the 5 CM2K
circuit continues to operate as if the corrector is turned off.
Troubleshooting: Call an authorized serviceman who will
check the corrector position, check the damage/accuracy of the
corrector and cable, check the contacts on the connectors.
Possible cause: Interruption in the cables between the 6
circuit sensor and CM2K, connections on the CM2K, cold
junction or defective sensor.
Boiler status: The boiler operates normally, the 6 CM2K
circuit stops to operate, stops (turns off) the pump.
Troubleshooting: Call an authorized serviceman who will
check the sensor position, check the damage/accuracy of the
sensor and cable , check the contacts on the connectors ,
check the sensor's ohm resistance.
Possible cause: Interruption in the cables between the 6
circuit corrector and CM2K, connections on the CM2K, cold
junction or defective corrector
Boiler status: The boiler operates normally, the 6 CM2K
circuit continues to operate as if the corrector is turned off.
Troubleshooting: Call an authorized serviceman who will
check the corrector position , check the damage/accuracy of
the corrector and cable, check the contacts on the connectors.
Possible cause: Interruption in the cables between the 7
circuit sensor and CM2K, connections on the CM2K, cold
junction or defective sensor.
Boiler status: The boiler operates normally, the 7 CM2K
circuit stops to operate, stops (turns off) the pump.
Troubleshooting: Call an authorized serviceman who will
check the sensor position, check the damage/accuracy of the
sensor and cable, check the contacts on the connectors, check
the sensor's ohm resistance.
Errors
th
th
th
th
th
th
th
th
th
th
87