Centrometal Cm Pelet-set Touch 14 Technical Manual page 34

The digital boiler controller
Hide thumbs Also See for Cm Pelet-set Touch 14:
Table of Contents

Advertisement

Heating configuration (markings on the display)
Example 4:
Configuration H10 - boiler connected with 4-WAY MIXING VALVE WITH ACTUATOR (backflow protection),
DHW tank and there is a possibility of controlling one or two direct central heating circuits (if one or more CM2K
modules with two heating circuits / DHW are not installed).
Example 5:
Configuration H20 - boiler connected with 4-WAY MIXING VALVE WITH ACTUATOR (backflow protection),
DHW tank with DHW recirculation and there is a possibility of controlling one or two direct central heating circuits
(if one or more CM2K modules are not installed for two heating circuits / DHW).
Example 6:
Configuration H70 - boiler connected with 4-WAY MIXING VALVE WITH ACTUATOR (backflow protection),
DHW tank installed in the boiler and there is a possibility of controlling one or two direct central heating circuits (if
one or more CM2K modules with two heating circuits are not installed / DHW).
Example 7:
Configuration H80 - boiler connected with 4-WAY MIXING VALVE WITH ACTUATOR (backflow protection),
DHW tank installed in the boiler, controlled and recirculated DHW and there is a possibility of controlling one or
two direct central heating circuits (if no one or more CM2K modules with two heating circuits are installed /
DHW).
Example 8:
Configuration H01 - boiler connected with 4-WAY MIXING VALVE WITH ACTUATOR (backflow protection) and
steers one central heating circuit with a motor mixing valve (there is no control of one or two direct central
heating circuits).
Example 9:
Configuration J71 - boiler connected with HYDRAULIC CROSSOVER via 4-way mixing valve with actuator
(backflow protection), DHW tank built into the boiler and steer one central heating circuit with a mixing valve with
actuator.
Remark:
Only configuration of H00, H10, H20, H70, H80 can be defined for directing one or two direct heating
circuits with or without a pump, room corrector or room thermostat only in the absence of one or more
CM2K modules for two circuits heating / DHW.
34
Technical manual - THE DIGITAL BOILER CONTROLLER Cm-Pelet set_Touch 14-90 kW