Heating configuration (markings on the display)
13.84.2. Configuration H-8-0
Temperatures: Tboiler:
- Mode:
dTboiler:
- Mode:
13.85. Configuration H-8-1
Temperatures:
Tboiler:
-> Heating+DHW: 80°C (70-90°C)
-> DHW: 70°C (70-80°C)
- Mode:
dTboiler:
- Heating+DHW: 10°C (5-15°C)
- Mode:
- DHW: 10°C (5-10°C)
13.86. Configuration I-0-0
Temperatures: Tboiler: 80°C (80-90°C)
dTboiler: 10°C (5-15°C)
Tbuf: 80°C (70-80°C)
dTbuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
66
Technical manual - THE DIGITAL BOILER CONTROLLER Cm-Pelet set_Touch 14-90 kW
-> Heating+DHW: 80°C (70-90°C)
-> DHW: 70°C (70-80°C)
- Heating+DHW: 10°C (5-15°C)
- DHW: 10°C (5-10°C)
Tdhw:
- Mode:
dTdhw:
- Mode:
*EKO-CKB P + Cm Pelet-set_Touch
20
3
bar
17
M
9 5
2
4
Tdhw:
- Heating+DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
- Mode:
dTdhw:
- Heating+DHW: 15°C (10-40°C)
- Mode:
- DHW: 15 (10-40°C)
*DIRECT HEATING CIRCUITS WITHOUT PUMPS
EKO-CKB P + Cm Pelet-set_Touch
20
3
bar
17
M
2
9 5
4
- Heating+DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
- Heating+DHW: 15°C (10-40°C)
- DHW: 15 (10-40°C)
EKO-CK P + Cm Pelet-set_Touch
3
bar
M
8
1
9
5
4
23
23
8
13
14
M
8
Circuit 1:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
11
10
12