Display, Info, Correction
- Show timers - this option allows a customer to have the timer of each
working phase displayed in the main screen. This option makes it
easier to monitor working phases of the burner and other components.
- Date & Time - current time and date adjusting. If those parameters are not correct, the scheduled times will not work
properly. If time gets reset to 00:00 and date is 1.1.2000. it is necessary to replace the battery on the controller display
(CR1220).
- Sound volume - to set one of the 3 volume levels or turn the sound off.
- Sound type - to select one of the 10 types of the sound.
7. INFO
This option is used to see various informations regarding regulation and burner.
Options:
- Statistics - it can be see working times of various parts (burner working / work in Heating type: DHW / rad plamenika u
Freezeng guard / start plamenika / vrijeme rada ventilatora plamenika / rad grijača / uključenje grijača / rad transportera / rad
pumpe P1)
- Software version - it can be see burner power (14kW, 20-35kW, 40/50kW ili 90kW), regulation software version and
WIFi ID number (if Cm WiFi-box is installed)
- Selected configuration - it can be see currently selected configuration
- Current file - it can be see which saved file is currently in use
- Select burner power - it can be see currently set burner power (it can be selected by an authorized serviceman only –
under PIN)
9. CORRECTION
This option is used make correction of pellet delivery. You can decrease delivery by 3 steps. Steps are factory configurated.
Icon changes according the set step.
"0" - no correction
"1" -> screw feeder supply reduction by 10%
"2" -> screw feeder supply reduction by 20%
"3" -> screw feeder supply reduction by 30%
It is recommended that the customer uses this option if there is, because of the type or quality of pellets, larger amount of
sediment left on the burner grate after burning cycle (with regular grate cleaning) or if the customer, during weighing (article
5.4. Weighing check), finds out that screw feeder delivers more pellets than the value entered in ''Weighing check'' table
under ''Last weighing''.