Centrometal Cm Pelet-set Touch 14 Technical Manual page 55

The digital boiler controller
Hide thumbs Also See for Cm Pelet-set Touch 14:
Table of Contents

Advertisement

13.61. Configuration E-7-1
Temperatures:
Tboiler:
- Mode:
dTboiler:
- Mode:
13.62. Configuration E-7-2
Temperatures:
Tboiler:
- Mode:
dTboiler:
- Mode:
13.63. Configuration E-8-0
Temperatures:
Tboiler:
- Mode:
dTboiler:
- Mode:
Technical manual - THE DIGITAL BOILER CONTROLLER Cm-Pelet set_Touch 14-90 kW
-> Heating+DHW: 80°C (75-90°C)
-> DHW: 70°C (75-80°C)
- Heating+DHW: 10°C (5-15°C)
- DHW: 10°C (5-10°C)
-> Heating+DHW: 80°C (75-90°C)
-> DHW: 70°C (75-80°C)
- Heating+DHW: 10°C (5-15°C)
- DHW: 10°C (5-10°C)
-> Heating+DHW: 80°C (75-90°C)
-> DHW: 70°C (75-80°C)
- Heating+DHW: 10°C (5-15°C)
- DHW: 10°C (5-10°C)
Heating configuration (markings on the display)
EKO-CKB P + Cm Pelet-set_Touch
20
3
bar
2
4
Tdhw:
- Mode:
- Heating+DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
dTdhw:
- Mode:
- Heating+DHW: 15°C (10-40°C)
- DHW: 15 (10-40°C)
EKO-CKB P + Cm Pelet-set_Touch
20
3
bar
2
4
Tdhw:
- Mode:
- Heating+DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
dTdhw:
- Mode:
- Heating+DHW: 15°C (10-40°C)
- DHW: 15 (10-40°C)
EKO-CKB P + Cm Pelet-set_Touch
20
3
bar
17
2
4
Tdhw:
- Mode:
- Heating+DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
dTdhw:
- Mode:
- Heating+DHW: 15°C (10-40°C)
- DHW: 15 (10-40°C)
22
14
M
5
21
6
Tcro: 75°C (70-80°C)
Circuit 1:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
22
15
M
5
6
21
Tcro: 75°C (70-80°C)
Circuit 1, Circuit 2:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
22
5
6
21
Tcro: 75°C (70-80°C)
13
13
13
14
M
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents