Installing/Removing the Server into the Rack
4.3.5

Mounting in 3rd-Party Racks

For mounting the server in a 3rd-Party Rack the following parts are necessary:
– support bracket
– two telescopic rails, telescopic bars and support rails
– two mounting brackets
– two cable support plates and cable holders
– possibly eight mounting springs (figure 5 on page 30)
Ê Take the original manual of the rack manufacturer regarding the mechanical
installation and/or the climatic conditions for assistance.
V
CAUTION!
With the installation in 3rd-Party Rack ensure that in the rack from
front to rear the air flow is accessible.
Ê Mount the necessary manufacturer original parts (like support bracket or
cable management).
I
Sometimes a series of parts from the delivered mounting kit cannot
be used because original parts of the 3rd-Party Rack are to be used.
Ê Mount the telescopic rails in the 3rd-Party Rack as described in section
"Mounting into the PRIMECENTER or into the DataCenter Rack" on page 30.
Ê Mount the server (see section "Mounting/Removing the Server" on page 35).
Ê Route the cables as described in the original manual of the Rack.
34
Hardware Installation
A26361-K875-Z102-3-7619