Installation In 3Rd Party Racks - Fujitsu PRIMERGY RX200 S3 Operating Manual

Hide thumbs Also See for PRIMERGY RX200 S3:
Table of Contents

Advertisement

Installing/Removing the Server in/from the Rack
4.2.2

Installation in 3rd Party Racks

The following parts are required to install the server in 3rd party racks:
– one left and one right telescopic rail (assembled)
– M5x10 screws with integrated plugwashers
I
– Or, M5x10 screws with separate plugwashers can also be used.
In this case, two plugwashers each must be fitted beforehand on
the support uprights and the support bracket.
– The descriptions and figures in this section refer to the current
variable support.
Ê Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.
V
CAUTION!
For installation in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê Fit the required original parts (support bracket or cable management
system).
I
Under certain circumstances, you will not be able to use some of the
parts from the rack installation kit supplied - you will need to use
original 3rd party rack parts instead.
Ê Remove the outer telescopic rail as described in
Racks with installation depth of 735 mm
The lengths of the telescopic rails do not need to be adjusted with respect to
each other for the installation in rack systems with 735 mm installation depth.
Ê Secure the telescopic rails as described in
CENTER/DataCenter Rack" on page
Ê Mount the server (see
the cables as described in the original manual of the rack.
38
35.
section "Inserting the server" on page
Operating Manual
Hardware Installation
page 36 (figure
section "Mounting in the PRIME-
4).
39) and route
RX200 S3

Advertisement

Table of Contents
loading

Table of Contents