Mechanical safety
Flown congurations
The A10 rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines
of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of 4 or more.
Refer to Soundvision for the safety factor of a specic deployment.
The safe limit gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-enclosure angles, etc.).
The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
KS21
conguration
Vertical array
Vertical array
A10 Wide/Focus
conguration
Flown
Vertical array
Vertical array
Radial array
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
Use safety straps
Always use safety straps on stacked arrays where the enclosures are not connected by the rigging system.
Always use safety straps on stacked arrays higher than four enclosures.
KS21
conguration
Stacked vertical array
Stacked upright
Stacked on chariot
A10 owner's manual (EN) version 1.1
rigging accessory
A15-BUMP
A15-RIGBAR
rigging accessory
X-BAR
A10-BUMP
A10-RIGBAR
1 × A10-LIFT
2 × A10-LIFT
3 × A10-LIFT
rigging accessory
No rigging accessory or KS21-OUTRIG (optional)
No rigging accessory
KS21-CHARIOT
safe limit
maximum limit
8
4
maximum / safe limit
1
8
4
1 or 3
2, 4, 5 or 6
7, 8 or 9
maximum / safe limit
Mechanical safety
16
4
3
3
45