Mechanical safety

Mechanical safety
Flown congurations
The X15 HiQ rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the
guidelines of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of 5 or higher.
Refer to Soundvision for the safety factor of a specic deployment.
The safe limit gives the maximum number of elements for which the safety factor is always compliant with the
2006/42/EC: Machinery Directive, regardless of the other deployment parameters (site angles, inter-enclosure angles,
etc.)
The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
X15 HiQ
Conguration
Flown
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
X15 HiQ
Conguration
Ground-stacked
Pole-mounted
SB18
Conguration
Ground-stacked

Assessing mechanical safety

Mechanical safety of the rigging system
Before any installation, always model the system in Soundvision and check the Mechanical Data section for
any stress warning or stability warning.
In order to assess the actual safety of any array conguration before implementation, refer to the following warnings:
Rated working load limit (WLL) is not enough
The rated WLL is an indication of the element resistance to tensile stress. For complex mechanical systems such as
loudspeaker arrays, WLLs cannot be used per se to determine the maximum number of enclosures within an array
or to assess the safety of a specic array conguration.
Mechanical modeling with Soundvision
The working load applied to each linking point, along with the corresponding safety factor, will depend on
numerous variables linked to the composition of the array (type and number of enclosures, splay angles) and the
implementation of the ying or stacking structure (number and location of ying points, site angle). This cannot be
determined without the complex mechanical modeling and calculation offered by Soundvision.
8
Rigging accessory
X-UTILT / X-US1215 / X-UL15 / X-BAR
Rigging accessory
No rigging accessory
35 mm pole / EMBi and X-US1215
Rigging accessory
No rigging accessory
Maximum / Safe limit
1
Maximum / Safe limit
1
1
Maximum / Safe limit
4
X15 HiQ rigging manual (EN) version 4.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X8X12Sb15mSb18

Table of Contents