Mechanical safety

Mechanical safety
Flown congurations
The Kiva II rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the
guidelines of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of 4 or more.
Refer to Soundvision for the safety factor of a specic deployment.
The safe limit gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-element angles, etc.).
The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Kiva II
conguration
rigging accessory
own
KIBU-SB
own
KIBU II
pullback
KIBU II / KIBU-SB + KIVA-PULLBACK
ceiling-mounted
KIET II
SB15m
conguration
rigging accessory
own
KIBU-SB
Kiva II + SB15m
conguration
rigging accessory
pullback
KIBU-SB + KIVA-PULLBACK
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
Kiva II
conguration
rigging accessory
stacked
KIBU-SB
pole-mounted
KIET II + 35 mm pole
pole-mounted
KIET II + 35 mm pole + SB15m
SB15m
conguration
ground-stacked
22
rigging accessory
no rigging accessory
safe limit
maximum limit
8
8
16
3
safe / maximum limit
8
maximum limit
9 Kiva II + 3 SB15m
safe limit
maximum limit
4
3
2
maximum / safe limit
4
Kiva II owner's manual (EN) version 3.0
20
20
9