JLG G10-55A Operation & Safety Manual page 129

S/n 0160045636 & after including 0160045082, 0160045094, 0160045209, 0160045295, 0160045296, 0160045449
Table of Contents

Advertisement

B. Element Change (as restriction indicator indicates)
1. Perform "Shut-Down Procedure" on page 4-4.
2. Unlock air cleaner cover (4) and remove from air cleaner canister.
3. Lightly remove any loose dirt from cover and precleaner (5).
4. Remove outer primary element (6) and inspect for damage. Damaged elements
should not be reused.
5. Thoroughly clean the interior of the air cleaner canister and vacuator valve.
6. Replace inner safety element (7) after every third primary element change. If
replacing the inner safety element at this time, carefully slide the element out
and replace with new element.
7. Slide the new primary element over the inner element making sure the sealing
edge is flush with the base of the air cleaner.
8. Position air cleaner cover in place and lock into position.
9. Depress button on restriction indicator to reset.
Note: An inner safety element should never be washed or reused. Always install a
new element.
31200745
Section 7 - Lubrication and Maintenance
7-15