Chapter12 IEEE488.2 Common Order

This chapter introduces IEEE488.2 Common Order for IT6800A/B series power
supply.

*CLS

This order can clean the register as follows:
Order syntax
*CLS
Parameter
None

*ESE

This order can set the parameter of standard event enable register. Setting
parameter can determine which bit value of standard event register is 1 and the
byte will enable ESB of status byte register is 1.
Order syntax
*ESE <NR1>
Parameter
0 to 255
Reset value
Consult *PSC order
Example
*ESE 128
Quest syntax
*ESE?
Return parameter
<NR1>
Reference order
*ESR?
*PSC
*STB?
Standard event status register
Quest condition register
Status byte register