Calibration:voltage [:Data] {<Numeric Value; Calibration:current:level; Calibration:current [:Data] {<Numeric Value; Calibration:string - ITech IT6800B Series Programming Manual

Dc programmable power supply
Hide thumbs Also See for IT6800B Series:
Table of Contents

Advertisement

Parameters
P1|P2|P3|P4
CALibration:VOLTage [:DATA] {<numeric value>}
Return actual output voltage value of calibration point.
Order syntax
CALibration:VOLTage [:DATA] <NRf>
Parameters
<NRf>
Example
CAL:VOLT 30.0002V

CALibration:CURRent:LEVel

This order can set current calibration point. P1、P2 must be calibrated orderly.
Order syntax
CALibration:CURRent:LEVel <point>
Parameters
P1|P2
CALibration:CURRent [:DATA] {<numeric value>}
Return actual output current value to calibration point.
Order syntax
CALibration:CURRent[:DATA] <NRf>
Parameters
<NRf>
Examples
CAL:VOLT 3.0002A

CALibration:STRing

Set the calibration information.
Order syntax
CALibration:STRing <parameters>
Parameters
The longest length is a string including 24 letters i.e related information the
customer records during running the calibration process, such as the calibration
Copyright © Itech Electronic Co., Ltd.
Calibration Commands
33