ITech IT6800B Series Programming Manual page 23

Dc programmable power supply
Hide thumbs Also See for IT6800B Series:
Table of Contents

Advertisement

customer through BIT4 bit. The data bits in Status byte group will not be
latched, when the information in event register is changed, the correspo0nding
bit in status byte register will subsequently be changed.
Bit
0-2
Not used
3
QUES
4
MAV
5
ESB
6
RQS
7
Not used
Copyright © Itech Electronic Co., Ltd.
Decimal
Value
0
Always set to 0.
8
One or more bits are set in the questionable
status
register (bits must be enabled in the enable
register).
16
Data is available in the power supply output
buffer.
32
One or more bits are set in the standard
event register (bits must be enabled in the
enable register).
64
The power supply is requesting service
(serial poll).
0
Always set to 0.
SCPI Status Register