Extended Protection Parameter (Group No. 06); Extended Panel Parameter (Group No. 07); Extended Communication Parameter (Group No. 08) - Toshiba VFS5 Series Operation Manual

Table of Contents

Advertisement

Display
Function
F600
Motor overload protection level (%)
F60I
Stall protection level (%)
F602
Fault trip saving
F603
Emergency stop selection
F604
Emergency DC inject time (s)
F605
Open phase detection parameter
Display
Function
F700
Parameter setting disable selection
F70I
Unit selection
F702
Frequency units multiplication factor
Extended Parameters (Communication Group No. 08)
Display
Function
F800
Communication speed
F80I
Parity
F802
Inverter number
F803
Communication error trip time (s)
TOSHIBA
Parameter List (cont'd)
Extended Parameters (Protection Group No. 06)
10 ~ 199, 200 (OFF)
0: No, 1: Yes
0: Coast to stop
1: Stopping after deceleration
2: Stopping by emergency DC braking
0: Not activated
1: Activated (first running only at start up
after power on)
2: Activated (running only at start up)
Extended Parameters (Panel Group No. 07)
0: Enable (except FMod and CMod in running)
1: Disable
2: Enable
0: Not changed
1: Change % into A, V
2: F702 enable
3: Convert % into A, V,
F702 enable
0.01 ~ 200.0
0 : 1200bps
1 : 2400bps
2 : 4800bps
3 : 9600bps
0 : NONE
1 : EVEN
2 : ODD
0 ~ 63
0 (OFF), 1 ~ 100
39
Adjustable range
10 ~ 100
0.0 ~ 20.0
Adjustable range
Adjustable range
Default
value
100
150
0
0
10
0
Default
value
0
0
1.00
Default
value
3
1
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents