Group:protection Function Parameters - Toshiba Tosvert-130 Installation Manual

Transistor inverter vector drive series
Table of Contents

Advertisement

8.3.7 GROUP:PROTECTION FUNCTION PARAMETERS

Reg.
Function / Title
11F
DYNAMIC BRAKING SELECTION
120
2
BRAKING RESISTOR VALUE
121
BRAKING RESISTOR POWER RATING
122
OVERVOLTAGE STALL PROTECTION
123
DC INJECTION START FREQUENCY
124
Other
DC INJECTION CURRENT MAGNITUDE
125
than 0
DC INJECTION TIME
126
FWD/REV DC INJECTION PRIORITY CTRL
127
MOTOR SHAFT STATIONARY CTRL
128
EMERGENCY OFF MODE SELECTION
129
2
EMERGENCY OFF DC INJECTION TIME
12A
NUMBER OF RETRY ATTEMPTS
12B
Other
TIME BETWEEN RETRY ATTEMPTS
than 0
12C
REGENERATION POWER RIDE-THROUGH
12D
1
REGENERATION RIDE-THROUGH TIME
12E
AUTO-RESTART (MOTOR SPEED SEARCH)
12F
ELECTRONIC THERMAL PROTECT LVL #1
130
OVERLOAD REDUCTION START FREQ
131
MOTOR 150% OVERLOAD TIME LIMIT
132
OVERLOAD SELECTION
133
STALL PROTECTION ENABLE
134
0
STALL PROTECTION CURRENT LEVEL
135
UNDERVOLTAGE TRIP SELECTION
136
UNDERVOLTAGE DETECT TIME
137
LOW CURRENT DETECT SELECTION
138
LOW CURRENT DETECT LEVEL
139
LOW CURRENT DETECTION TIME
140
OUTPUT SHORT-CIRCUIT DETECTION SELECT
141
OVERTORQUE TRIP SELECTION
142
OVERTORQUE TRIP LEVEL
Bank
Address
(Note)
0 / 1
04BD
0 / 1
0416
0 / 1
0418
0 / 1
04BD
0 / 1
03FC
0 / 1
043A
0 / 1
043B
0 / 1
04BC
0 / 1
04BC
0 / 1
04BC
0 / 1
043D
0 / 1
043F
0 / 1
0440
0 / 1
04BD
0 / 1
0446
0 / 1
04B6
0 / 1
042A
0 / 1
0410
0 / 1
0444
0 / 1
04BD
0 / 1
042D
0 / 1
042B
0 / 1
04BD
0 / 1
0414
0 / 1
04BC
0 / 1
0441
0 / 1
0442
0 / 1
04BE
0 / 1
04BE
0 / 1
0443
22
Mask
Adjustment Range
0003
0000: no dynam. Braking
0001: with dynamic braking,
no DBR OL trip
0002: with dynamic braking
and DBR OL trip
FFFF
000A ∼ 2710 (1.0 ∼ 1000)
FFFF
0001 ∼ EA60 (0.01 ∼ 600.00)
0004
0000: ON
0001: OFF
FFFF
0000 ∼ 2EE0 (0.00 ∼ 120.00)
00FF
0000 ∼ 0064 (0 ∼ 100)
00FF
0000 ∼ 0064 (0.0 ∼ 10.0)
0040
0000: OFF
0001: ON
0080
0000: OFF
0001: ON
0030
0000: Coast stop
0001: Decelerated stop
0002: DC injection stop
00FF
0000 ∼ 0064 (0.0 ∼ 10.0)
00FF
0000 ∼ 000A (0 ∼ 10)
00FF
0000 ∼ 0064 (0.0 ∼ 10.0)
0008
0000: OFF
0001: ON
00FF
0000 ∼ 00FA (0.0 ∼ 25.0)
0018
0000: OFF
0001: On power failure
0002: On ST make/break
0003: Both (1) and (2)
00FF
000A ∼ 0064 (10 ∼ 100)
FFFF
0000 ∼ 0BB8 (0.00 ∼ 30.00)
00FF
0001 ∼ 00F0 (10 ∼ 2400)
0030
0000: with motor overload trip,
w/o soft-stall
0001: with motor overload trip
and soft-stall
0002: w/o soft-stall or motor
overload trip
0003: with soft-stall, w/o motor
overload trip
0040
0000: ON
0001: OFF
00FF
000A ∼ 00D7 (10 ∼ 215)
0080
0000: Trip disabled
0001: Trip (during run)
FFFF
0000 ∼ 03E8 (0.00 ∼ 10.00)
0008
0000: Trip disabled
0001: Trip on detection
00FF
0000 ∼ 0064 (0 ∼ 100)
00FF
0000 ∼ 00FF (0 ∼ 255)
0003
0000: Standard motor
0001: High-speed motor
0002: Positioning use
(standard motor)
0003: Positioning use (high-
speed motor)
0040
0000: Trip disabled (0)
0001: Trip enabled (1)
00FF
0000 ∼ 00C8 (0 ∼ 200)
Multiplier
0.1
0.01
0.01
1
0.1
0.1
1
0.1
0.1
1
0.01
10
1
0.01
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents