3. Using the control dial, select/confirm an item or specify/confirm a value.
(In this example, "Panel / LCD-option" is selected and confirmed or frequency of 90.0Hz is specified and
confirmed.)
When the change you made is saved, the title of the
parameter stops blinking and the screen returns to the
previous window.

4.3 Setting an extended parameter

1. Select/confirm "Extended parameters" using the control dial.
The Extended Parameters window appears.
Functions of function keys
: Displays parameters in the number range of 900.
F1
The number displayed decrements each time this key
is pressed.
: Displays the previous window.
F2
: Displays the next window.
F3
: Displays parameters in the number range of 900.
F4
The number displayed increments each time this key
is pressed.
2. Change the parameter setting.
To do this, perform steps 2 and 3 in the "3.2 Setting a basic parameter" section.
• If the setting selected is
changed by selecting a
menu
0 :Terminal
1 :Panel / LCD-option
2 :RS485-2wire
3 :RS485-3wire
• If the setting selected is
changed by specifying a
value
min=25.0
×1000
F100 :Low-speed signal freq
F101 :Speed reach frequency
F102 :Speed reach freq band
F105 :Priority of FWD/REV
F106 :Input terminal priority
F9--
F1
D-3
E6581429
Basic Parameters
CMOd
Command input mode
Basic Parameters
vL
Base frequency 1
90.0
Hz
max=500.0
×100
×10
×1
Parameter Setup Mode
Extended Parameters
F2--
F2
F3
F4
4