Extended I/O Parameter (Group No. 01); Extended Frequency Parameter (Group No. 02) - Toshiba VFS5 Series Operation Manual

Table of Contents

Advertisement

Display
Function
FI00
Low speed signal output (Hz)
FI0I
Speed reach HI frequency (Hz)
FI02
Acc/Dec complete detection
bandwidth (Hz)
FI03
ST signal selection
FI04
RST signal selection
FII0
Always active function selection
FIII
Input terminal selection #1
FII2
Input terminal selection #2
FII3
Input terminal selection #3
FII4
Input terminal selection #4
FII5
Input terminal selection #5
FI30
Output terminal selection #1
FI3I
Output terminal selection #2
Display
Function
F200
Frequency priority selection
F20I
VIA reference point #1 (%)
F202
VIA point #1 frequency (Hz)
F203
VIA reference point #2 (%)
F204
VIA point #2 frequency (Hz)
F2I0
VIB reference point #1 (%)
F2II
VIB point #1 frequency (Hz)
F2I2
VIB referfence point #2 (%)
F2I3
VIB point #2 frequency (Hz)
F240
Start-up frequency (Hz)
F24I
Run frequency (Hz)
F242
Run frequency hysteresis (Hz)
F250
DC injection starting frequency (Hz)
F25I
DC injection current (%)
F252
DC injection time (s)
F260
Jog run frequency (Hz)
F26I
Jog stop control
F270
Jump frequency #1 (Hz)
F27I
Jump frequency band #1 (Hz)
F272
Jump frequency #2 (Hz)
F273
Jump frequency band #2 (Hz)
F274
Jump frequency #3 (Hz)
F275
Jump frequency band #3 (Hz)
F280
Preset speed 1 to 15 (Hz)
-F284
TOSHIBA
Parameter List (cont'd)
Extended Parameters (I/O Group No. 01)
0.0 ~ FH
0.0 ~ FH
0.0 ~ FH
0: Standard, 1: Normally ON, 2: Linking with F/R
0: Standard, 1: Resetting if no signal is input to terminal
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 37 Refer to Input Terminal Selection table page 51.
0 ~ 9 Refer to Output Terminal Selection table page 52.
0 ~ 9 Refer to Output Terminal Selection table page 52.
Extended Parameters (Frequency Group No. 02)
0: Ramp to stop 1: Coast to stop 2: DC
37
Adjustable range
Adjustable range
0 : VIA, II 1 : VIB
0 ~ 100
0.0 ~ 320.0
0 ~ 100
0.0 ~ 320.0
0 ~ 100
0.0 ~ 320.0
0 ~ 100
0.0 ~ 320.0
0.5 ~ 10.0
0.0 ~ FH
0.0 ~ FH
0.0 ~ FH
0 ~ 100
0.0 ~ 20.0
0.0 ~ 20.0
LL ~ UL
0.0 ~ 30.0
LL ~ UL
0.0. ~ 30.0
LL ~ UL
0.0 ~ 30.0
LL ~ UL
Default
value
0.0
0.0
2.5
1
0
0: No function
provided
2 : F
3 : R
10 : RST
6 : S1
7 S2
4 : LOW
6 : RCH
Default
value
0
0
0.0
100
80.0
0
0.0
100
80.0
0.5
0.0
0.0
0.0
30
1.0
0.0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0