Electrical Connections
Main Control Cabinet
WARNING:
Electrocution may occur when working on energized circuits. Disconnect
power at the main breaker or service disconnect switch, then lock out and
tag it to indicate that work is being performed on the circuit.
•
Install the wall-mounted control cabinet 48"/1219 mm above the finished floor. Junction boxes
are located on the grinder and the waterpress as well. Remote systems have an additional Emergency
Stop on the waterpress.
•
Factory conduit/wire assemblies are located in the
•
Additional holes and wiring not supplied at the factory must be supplied by others and installed
in the same * areas.
•
Electrical schematics are located inside the wall-mounted control cabinet.
*
*
*
*
marked areas.
16 7 16 "
11"
10 1 4 "
7
16 "
*
48"
FFL
Fig. 10
•
Ensure the UL508A Data Plate electrical requirements match the installation site.
•
Connect incoming power to the control cabinet input terminal block.
•
If required, connect the control wires at the terminals to the left of the PLC.
•
If required, onnect the motors at the bottom of the control cabinet.
C
25 9 16 "
26 7 8 "
D
L1 L2 L3
Model:
Maximum Voltage:
Total FLA:
Largest Motor FLA:
Phase:
Hertz:
Field Wiring Diagram:
SCCR:
B
Cabinet Type:
Electrical Connection
40
41
42
43
44
45
46
47
48
49
50
51
Grinder
Slurry
Water Pres
Recirc
Mtr.
Mtr.
Mtr.
Mtr.
Fig. 11
Installation
A
B
C
D
Champion Industries, Inc.
Winston-Salem, N.C.
SSG
VAC
Amps
Amps
3 PH
60 Hz
703054
5000 Amps
NEMA 4X
UL508A
Data Plate
A
9