Run Mode - Balancing the System
•
The HMI shows 'READY' when the waterpress is full of water.
•
The green start/stop station button turns solid green.
•
Push the flashing green start/stop station button. System runs.
- HMI shows "RUNNING".
PRESS STOP FOR CLEAN
I/O
•
All pumps run, Waterpress and grinder run, Trough gusher runs.
•
Set the waterpress recirc valve (A) three quarter open.
•
Set the trough flush valve (B) three quarter open.
Recirc
Tank
Recirc Pump
•
Set the waterpress recirc valve (A) 3/4 turn open.
•
Set the trough flush valve (B) 3/4 turn open.
- WITHOUT LOADING WASTE -
•
The waterpress water level will be at or below the middle float.
•
The recirc pump and the slurry pump will cycle back and forth. This is normal.
•
There should be good water flow in the water trough.
RUNNING
A
Drain
Slurry Tank
Slurry Pump
Fig. 17
Continued on next page.
Operation
Trough
B
19