Feed Trough Cleaning
DANGER
DO NOT OPERATE
WITHOUT GUARDS
IN PLACE
P/N 116135
Perform a Clean Mode and stop the system.
Inspect for any metal objects in the trough and remove.
Wipe the interior of the trough with a soft cloth. Do not use metal scouring pads.
Open the grinder access door and inspect the grinder teeth for metal objects.
Contact a supervisor if metal is observed and disconnect main power to the
system.
Cleaning for Extended Shutdown
Perform a Clean Mode and stop the system.
Open the slurry tank drain valve(s) and drain the tank.
Close the valves.
Press the green start/stop station button to fill the machine.
Run the machine for 10 minutes.
Perform another Clean Mode.
Cleaning complete.