Installation
Electrical Connections
(continued)
Conduit Routing
Note the illustrations to the right for close-coupled and remote systems.
Close-coupled systems:
•
Contains: main control cabinet, grinder and waterpress junction boxes,
start/stop station.
•
Whips: 20' waterpress/control cabinet, 20' grinder/control cabinet,
12' grinder to start/stop station.
•
Whips and junction boxes labeled for easy identification.
10
Checking Motor Rotation
•
All the motors are wired to rotate in the same direction at the factory.
Proper motor rotation is clockwise when viewed from the rear.
•
To reverse motor rotation: DISCONNECT MAIN POWER. Reverse
L1 and L2 wires at the input terminal block located at the top of the
main control cabinet. Reconnect power and bump the motors to verify
the motor rotation is correct.
G-1
(Supplied by others)
20' Whip
REMOTE
S-1
12' Whip
G-1
S-1