Conduit Routing; Checking Motor Rotation - Champion TRISYS SSG M3 Installation, Operation, And Cleaning

Waste systems, slow speed grinder and waterpress, close-coupled and remote
Table of Contents

Advertisement

Installation
Electrical Connections
(continued)

Conduit Routing

Note the illustrations to the right for close-coupled and remote systems.
Close-coupled systems:
Contains: main control cabinet, grinder and waterpress junction boxes,
start/stop station.
Whips: 20' waterpress/control cabinet, 20' grinder/control cabinet,
12' grinder to start/stop station.
Whips and junction boxes labeled for easy identification.
10

Checking Motor Rotation

All the motors are wired to rotate in the same direction at the factory.
Proper motor rotation is clockwise when viewed from the rear.
To reverse motor rotation: DISCONNECT MAIN POWER. Reverse
L1 and L2 wires at the input terminal block located at the top of the
main control cabinet. Reconnect power and bump the motors to verify
the motor rotation is correct.
G-1
(Supplied by others)
20' Whip
REMOTE
S-1
12' Whip
G-1
S-1

Advertisement