Note:
Mounting the Branch Gateway in the rack
About this task
Use this procedure to mount the Branch Gateway in the rack.
Before you begin
The power supply must be disconnected before mounting the Branch Gateway.
Procedure
1. Insert two mounting screws, one on either side of the rack.
These will be the bottom screws of the mounting brackets. Turn the screws only 3-4 times,
so that a part of them is protruding.
2. Position the Branch Gateway in the rack so that the bottoms of the brackets are resting on
the protruding screws.
3. Position the Branch Gateway in the rack.
Ensure that there is adequate ventilation.
4. Insert four rack mounting screws, two on each side.
5. Verify that the Branch Gateway is level and horizontal.
6. Tighten the rack mounting screws.
Avoid overtightening.
7. Either tighten the two bottom-most screws, or remove them completely.
8. Verify that ventilation vents are not obstructed.
Result
At this point, you have mounted the Branch Gateway chassis in the rack and are ready to insert
media modules as required in the planning documentation.

Mounting the Branch Gateway chassis

You can mount the Branch Gateway in a rack, on a wall, or on a table.
Electrostatic alert:
When handling any components of an S8300 Server or Branch Gateway, wear an anti-static
wrist ground strap. Connect the strap to an approved ground, such as an unpainted metal
surface.