PCAN-LIN – User Manual
General-purpose gateway (or router when using Acceptance
Code / Acceptance Mask feature) from:
 RS-232 to LIN (and back)
 RS-232 to CAN (limited bandwidth)
 CAN to LIN (and back)
Simulation of LIN slaves. Data can be changed via CAN frames
Processing a user-definable LIN ID list (scheduler with limited
number of entries, cyclic handling if required)
Individual LIN frames can be initiated via CAN or RS-232
High-speed (ISO 11898-2) or Low-speed (ISO 11898-3) CAN
transceiver module
Galvanic isolation between RS-232 and CAN/LIN up to 1 kV (only
for High-speed CAN)
Voltage supply from 9 to 30 V
Extended operating temperature range from -40 to 85 °C
(-40 to 185 °F)
1.2

Operation Requirements

Voltage supply:
 Modules up to ser. no. 999: 8 - 18 V DC
 Modules from ser. no. 1000: 9 - 30 V DC
For the connection to the computer: RS-232 extension cable D-
Sub 9-pin, RS-232 connector on the computer
For the supplied configuration software:
Windows 10, 8.1, 7 (32/64-bit)