PCAN-LIN – User Manual
5.3
Gateway LIN - RS-232
Properties
LIN master
Controlling of LIN bus via RS-232
Data is transmitted to LIN slaves or requested from them via RS-
232 command
Profile in the Configuration Tool
Inter-
Parameter
face
RS-232
Bit rate
CAN
Activation
LIN
Activation
Bit rate
Forward Mask
Filter Mask
Filter Code
Master Status
LIN Bus
Termination
Scheduler
Entries
Slave ID + Data
Configuration
Frame
Configuration
CAN ID for Slave
Activation
Bold = required modification compared to the default setting
Setting
Application-specific
No
Yes
Application-specific
RS-232
0xFF
0x00
Inactive
Master
Disabled
Application-specific
Disabled
20
Comment
All LIN frames are received
Schedule table not processed
Not relevant
(see Master Status)