Gateway Lin - Can - Peak PCAN-LIN Series User Manual

Interface for lin, can, and rs-232
Table of Contents

Advertisement

PCAN-LIN – User Manual
3.
Confirm the questions. In this context, the configuration is
permanently saved in the module and the module is reset in
order to activate the new configuration.
5.1

Gateway LIN - CAN

Properties
LIN master
Monitoring of the LIN bus via CAN
CAN frames initiate the transmission of LIN frames
Transmission of a data frame on the LIN bus by transmitting a
CAN data frame
Request of a data frame on the LIN bus by transmitting a CAN
remote frame
Profile in the Configuration Tool
Inter-
Parameter
face
RS-232
Bit rate
CAN
Activation
Bit rate
Forward Mask
Filter Mask
Filter Code
CAN ID Offset
CAN Error ID
Setting
Yes
Application-specific
LIN
LIN & RS-232
0xFFFFFFFF
0x00000000
0x000 (11 bits)
CAN ID
16
Comment
RS-232 for diagnostic purposes
All CAN frames are received
CAN ID = CAN ID Offset + LIN ID
LIN ID = CAN ID - CAN ID Offset
For transmission of error and
status messages. Is activated via
LIN > Forward Mask > CAN
Error.

Advertisement

Table of Contents
loading