PCAN-LIN – User Manual
Inter-
Parameter
face
LIN
Activation
Bit rate
Forward Mask
Filter Mask
Filter Code
Master Status
LIN Bus
Termination
Scheduler
Entries
Slave ID + Data
Configuration
Frame
Configuration
CAN ID for Slave
Activation
Bold = required modification compared to the default setting
Setting
Yes
Application-specific
CAN
0xFF
0x00
Inactive
Slave
Disabled
Application-specific
Disabled
22
Comment
RS-232 also possible
All LIN frames are received
Schedule table not processed
Not relevant
(see Master Status)