Safety; General Safety And Accident Prevention Regulations - Tormax Automatic Smart Drive 1101 Manual

Installation on site for automatic swing doors swingdoor
Table of Contents

Advertisement

General safety Instructions
2

Safety

2.1
General Safety and Accident Prevention
Regulations
Prior to installation or commissioning, read and follow this information that is being
described on this page—especially the following notes relating to safety—and adhere to
them at all times! Damage to the unit and personal injury may result if these instructions
!
were not carefully followed.
Pay particular attention to the specially marked notes in this manual (for an explanation
of the symbols please refer to chapter 1)!
These products are Underwriters Laboratories, Inc. (UL) listed and cUL certified for
the Canadian marketplace, and therefore comply with the requirements of the
National Electrical Code (NEC) and the Canadian Electrical Code (CEC). Installa-
tions intended to meet UL and cUL requirements must be followed as described in
the instruction provided herein. These are minimum standard requirements.
Where local codes exceed these requirements, they must be followed as well.
Preventing General Hazards and Possible Damage to This Equipment
• Keep fingers away from all moving parts.
• Verify that the power selection switch is set to the correct voltage before start-up.
• The power supply cable (flexible cord) should be entered at the end side that is close
to the input power supply plug. It should not be routed through doorways, window
openings, walls, ceilings, floors, etc. The power supply cable (flexible cord) should not
be attached or otherwise secured to the building structure. It should not also be
concealed behind walls, etc.
• Never allow the power supply cable (flexible cord) to become entrapped in moving
parts of the operator, door, or system.
• The power receptacle must be of the grounding-type. It is very important that the unit
will be properly grounded.
• To reduce the risk of electrical shock, this equipment has a grounding-type plug that
has a third grounding pin. This plug will only fit into a grounding-type outlet. If the plug
does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do
not change the plug in any way.
Warnings of Dangerous Electrical Voltages or Current
• Be sure the electrical power is disconnected and locked-out when working on the
operator unit.
• Install the electrical cables and power only after the mechanical installation to the unit
is done.
• Turn on the power to the operator unit only after all internal cables are connected. Do
not connect cables while the unit is powered.
• Always use appropriate tools for installation and repair.
Prior to commissioning or performing any work on the door system, the operating
instructions for the TORMAX operator and the following safety directions should be
studied with great care and must be observed!
In any case, please pay attention to the specially marked notes within this document (see
chapter 1 for an explanation of symbols).
Installation On Site SWINGDOOR Smart Drive 1101 T-1132 e