Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
<Fusing/Exit Misfeed>
Type
Leading edge detection by
Paper Exit Switch S53
Trailing edge detection by
S53
Detection Timing
S53 is not deactuated even after the lapse of approx. 2 sec. after the
TRON signal has been input.
S53 is not actuated even after the lapse of approx. 2.5 sec. after PC55
has been unblocked (H).
T-23