Level History - Minolta EP5000 General, Mechanical/Electrical

Hide thumbs Also See for EP5000:
Table of Contents

Advertisement

Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
1156SBS050410A

10. Level History

D This function is used to show and set the various level histories which were changed according to the
operating conditions of the copier and user requirements.
Touch Panel
Display
Level History
Touching the Level History key will show the various level histories as detailed
below. Of all data displayed, only that for "ATDC Ref. Value" and "Fuser
Temp. Control" can be changed.
– ATDC Ref. Value –
D Change this data when the RAM Board has been changed or a Developing
– Fuser Temp. Control –
D Change this data if fusing performance becomes poor due to the operating
Tech. Rep. Mode " Level History
Unit from another copier has been installed.
environment and the paper being used.
<Level History 1/2>
Display
Variable Range
ATDC Ref. Value
2 to 254
ATDC Target Level
1.0 to 9.0 (%)
ATDC Current Level
1.0 to 9.0 (%)
Vg Default Level
400 to 850 (V)
Vg Current Level
400 to 850 (V)
<Level History 2/2>
Display
Variable Range
Fuser Temp. Control
180 to 200 (°C)
Fuser Temp. Current
160 to 220 (°C)
Expo. Default Level
49 to 71 (V)
Expo. Current Level
49 to 71 (V)
Toner Replenishing
0 to 1270 (mm)
Time
S-39
Setting
Incre-
Description
ments
2 step
F8 adjusted value
0.5 (%)
Target ATDC level
0.5 (%)
Current ATDC level
30 (V)
Initial grid voltage
30 (V)
setting
Grid voltage correc-
tion value due to
changes with time
Incre-
Description
ments
10 (°C)
Target fusing tem-
perature
10 (°C)
Current fusing tem-
perature
1 (V)
Initial Exposure
Lamp level setting
1 (V)
Exposure Lamp lev-
el correction value
due to changes with
time
10 steps
Cumulative time of
toner replenishing