J3 Armature Voltage (90V); J3 Armature Voltage (180V); J5 Speed /Torque; Speed Mode Vs. Motor Load - KB Electronics Penta Power KBRG-212D Installation And Operation Manual

Regenerative drive, variable speed scr control full wave 4-quadrant
Hide thumbs Also See for Penta Power KBRG-212D:
Table of Contents

Advertisement

7.2 J3
Armature
Output and Tach-Generator
Feedback
desired armature voltage by
placing J3 in the proper
position, "A90" or "A180."
See Figure 11A.
Note:
For
line input, J3 must be
set to "A90." For 230
input, the armature
voltage is normally
set for "A180." However, it is also possible to set the armature voltage to "A90" for
stepdown operation.
7.2.1 Tach-Generator Feedback (for use with 1800 RPM motors.) – Jumper J3 is also
used if tach-generator feedback is to be used. If a 7 volt per 1000 RPM tach-
generator is used, set jumper J3 in the "T7" position. For a 50 volt per 1000 RPM
tach-generator, set the jumper in the "T50" position. See Figure 11B.
Note: When using tach-generator feedback, the
IR Comp Trimpot (See Section 10.4, on
page 27) should be turned to a
minimum setting (full CCW). See
Figure 9, and Section 6.11, on page 19.
7.3
J5 - Speed (SPD) or Torque (TRQ).
Note: Factory setting of J5 is Speed
mode (Default).
In the speed control mode (J5 set to SPD), the
KBRG-212D will provide variable speed
control. The motor speed will be in direct
proportion to the input signal. Both forward and
reverse torque is used to stabilize motor
speed.
See Figures 12, 13 and 14.
20
Voltage
Select
the
115
volt
AC
FIGURE 13 – SPEED MODE vs. MOTOR LOAD
100
HIGHER SET SPEED
90
80
70
60
50
40
30
20
10
LOWER SET SPEED
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
FIGURE 11A – J3
ARMATURE VOLTAGE
(90V)
SPEED / TORQUE (SPD or TRQ)
APPLIED TORQUE
FIGURE 11B – J3
ARMATURE VOLTAGE
(180V)
(Default Position)
FIGURE 12 – J5
Default Position
(Shown in the Torque Mode)
CL SETPOINT